Fictron Industrial Supplies Sdn Bhd
No. 7 & 7A,
Jalan Tiara, Tiara Square,
Taman Perindustrian Sime UEP,
47600 Subang Jaya,
Selangor, Malaysia.
No. 7 & 7A,
Jalan Tiara, Tiara Square,
Taman Perindustrian Sime UEP,
47600 Subang Jaya,
Selangor, Malaysia.
+603-8023 9829
+603-8023 7089
Penang Office:
44A Jalan Besi,
11600 Green Lane,
Penang, Malaysia.
+604-6192582
+604-6192583
fictronpgsales@fictron.com
Fictron Industrial
Automation Pte Ltd
140 Paya Lebar Road, #03-01,
AZ @ Paya Lebar 409015,
Singapore.
+65 31388976
sg.sales@fictron.com
44A Jalan Besi,
11600 Green Lane,
Penang, Malaysia.
+604-6192582
+604-6192583
fictronpgsales@fictron.com
Fictron Industrial
Automation Pte Ltd
140 Paya Lebar Road, #03-01,
AZ @ Paya Lebar 409015,
Singapore.
+65 31388976
sg.sales@fictron.com
170M2700 BUSSMANN High Speed Fuse Link Supply Malaysia Singapore Indonesia USA Thailand
Previous | 75 / 156 | Next |
RM 23.99
NH fuse switch-disconnector, 160A, 500V/160A, 690V/100A, size 00
Safety switch-disconnector, rated operational current 160A, max. fuse-link 500V/160A, max. fuse-link 690V/100A, size 00, connection top or bottom
Delivery program
For fitting on mounting plate
Number of poles
3 pole
Rated operational current [Ie]
160 A
Max. fuse
500 V
160 A
690 V
100 A
Frame size
NH00
Technical data
General
Standards
IEC/EN 60947-3
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
-20 - +55 °C
Altitude
Max. 2000 m
Mounting position
Vertical or horizontal
Overvoltage category/pollution degree
III/3
Degree of protection, from the frontOperational state
IP20
Degree of protection, from the frontFront cover open
IP10
Direction of incoming supply
as required
Lifespan, mechanical [Operations]
1700
Weight
0.72 kg
Contacts
Rated operational voltage [Ue]
500 V AC
Rated operational voltage [Ue]
220 V DC
Rated operational current [Ie]
160 A
Rated frequency [f]
40 - 60 Hz
Rated conditional short-circuit current AC [Iq]
50 kAeff
Rated conditional short-circuit current, DC [Iq]
25 kArms
Utilization category AC22BRated making capacity
480 A
Utilization category AC22BRated breaking capacity
480 A
Utilization category DC21BRated making capacity
150 A
Utilization category DC21BRated breaking capacity
150 A
Lifespan, electrical [Operations]
300
Lifespan, mechanical [Operations]
1700
Heat dissipation at IthAC, without NH-SE
6.9 W
Heat dissipation at IthDC, without NH-SE
4.6 W
Rated insulation voltage [Ui]
750 V AC
Rated impulse withstand voltage [Uimp]
8 kV
Rated insulation voltage [Ui]
750 V
Max. fuse
Frame size
NH00
Max. rated current, gL/gG
160 A
Max. admissible heat dissipation NH-SE [Pv]
12 W
Terminal capacity
Box terminalStranded
1.5 - 70 mm2
Box terminalCopper strip [Number of segments x width x thickness]
6 x 9 x 0.8 mm
Box terminalTightening torque
2.6 Nm
Box terminalStranded copper
1.5 … 70 mm2
Technical data ETIM 7.0
Low-voltage industrial components (EG000017) / Fuse switch disconnector (EC001040)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Fuse switch disconnector (ecl@ss10.0.1-27-37-14-01 [AKF058013])
Version as main switch
No
Version as safety switch
No
Max. rated operation voltage Ue AC
690 V
Rated permanent current Iu
160 A
Rated operation power at AC-23, 400 V
64 kW
Conditioned rated short-circuit current Iq
50 kA
Rated short-time withstand current lcw
50 kA
Suitable for fuses
NH00
Number of poles
3
With error protection
No
Type of electrical connection of main circuit
Screw connection
Cable entry
Equipped with connectors
Suitable for ground mounting
No
Suitable for front mounting 4-hole
No
Suitable for busbar mounting
Yes
Type of control element
Rocker lever
Position control element
Front side
Motor drive optional
No
Motor drive integrated
No
Version as emergency stop installation
No
Degree of protection (IP), front side
IP20
Dimensions